Engineering
Reliability and safety studies
Risk assessment, failure analysis and verification of safety functions, for machinery, equipment and industrial processes.
Services
Risk assessment
Identification of hazards and hazardous situations, risk estimation and evaluation, risk reduction measures, residual risk. Design-stage assessments, risks to people and to property in the operator’s care.
FMEA and FMECA
Failure modes, effects and criticality analysis. Functional or hardware approach, at system or component level.
Fault tree analysis
Logic model of a top event, minimal cut sets, probability or frequency calculation, common cause failures.
SIL safety functions
Allocation of the required level, architecture, calculation of PFDavg or PFH, architectural constraints, common cause failures, proof test intervals.
Performance level (PL)
Determination of the required PL, category, MTTFD, diagnostic coverage, common cause failures, PFHD.
Reliability and availability
MTBF, MTTR, downtime, contribution of each item of equipment. Markov models or Petri nets where the dependencies in the system call for them.
How a study is carried out
A study has four stages. Their content is adapted to the scope and to the standards that apply to the project.
Scoping
Scope, system boundaries, applicable standards, available input data.
Analysis
Risk assessment or FMECA. Risks that are not acceptable give rise to requirements.
Verification
Architectures, SIL or PL calculations, fault trees. The results are carried back into the assessment.
Reporting
Study report, list of deviations and actions, presentation of the results.
Deliverables
Study report
The report sets out the assumptions, the sources of the reliability data, the equations and the intermediate results, so that the calculations can be checked.
On request, the DepenLoop project file for the study is supplied with the report, so that the analysis can be updated later.
Page taken from a report produced by DepenLoop on the demonstration project (in French).
Standards
Each study follows the framework that applies to the project: regulations, international or sector standards, client specifications.
The texts below are the ones most often used. The list is not exhaustive.
- Risk assessmentISO 12100, ISO/TR 14121-2, ISO 31000, IEC 31010, IEC 61882
- Failure mode analysisIEC 60812
- Fault trees, event trees, reliability block diagramsIEC 61025, IEC 62502, IEC 61078
- Markov models, Petri netsIEC 61165, IEC 62551
- Functional safetyIEC 61508, IEC 61511, IEC 62061, ISO 13849-1, ISO 13849-2
- Reliability, availability, maintainabilityIEC 60300-1, IEC 60300-3-1, IEC 61703, IEC 61709, ISO 14224
Where a project falls under a product standard, a sector standard or a client specification, the study is carried out to that text.
Machinery in the European Union: Directive 2006/42/EC, replaced by Regulation (EU) 2023/1230 from 20 January 2027.
Limits of the service
Certification
Sigmastra is not a notified body. A study does not replace assessment by a notified body, nor the responsibility of the manufacturer or operator.
Reliability data
Data come from the manufacturer or from a cited source. Otherwise, the assumption used is stated, together with its effect on the result.
Application of standards
Common cause failures and architectural constraints are taken into account wherever the applicable standard requires it.
Study request
Please indicate the system concerned, the applicable standards, the documents available and the deadline.
contact@sigmastra.com